Technical data
| General | |
|---|---|
| Structure | Basic Contact Probe |
| Type/family | HCF360 |
| Pitch (mm/mil) | 3,70 / 145 |
| Temperature | -45°C...+200°C |
| Dimensions | |
|---|---|
| Total length (mm) | 4.9 |
| Protrusion height (mm) | 2.4 |
| Tip style diameter (mm) | 1.3 |
| Barrel diameter (mm) | 2.5 |
| Collar diameter (mm) | 2.8 |
| Press ring diameter (mm) | 2.8 |
| Materials and surfaces | |
|---|---|
| Tip style | 11 |
| Plunger material | Beryllium copper |
| Plunger plating | Gold |
| Barrel material | Brass |
| Barrel plating | Gold |
| Spring material | High-grade steel |
| Spring plating | Uncoated |
| Mechanical specifications | |
|---|---|
| Preload (cN) | 50 |
| Spring force (cN) | 80 |
| Nominal travel (mm) | 0.8 |
| Maximum travel (mm) | 1.2 |
| Pointing accuracy +/- (mm) | 0.1 |
| Thread | M2,5 |
| Tool size (mm) | 2,2 |
| Electrical specifications | |
|---|---|
| Continuous current (A) | 15 |
| Typical contact resistance (mOhm) | 15 |
Graphics
Beschreibung des Produkts
The High Current Probe HCF36011B130G080 (item number 1012191) is designed for safe transmission of high electrical currents in test and contacting applications. HCF36011B130G080 focuses on current capacity and low transition losses, as required in battery testing, formation and other e-mobility applications. For HCF36011B130G080, contact resistance, contact force and thermal behavior must be considered together because they influence voltage drop and temperature rise at the contact point. The intended application area for HCF36011B130G080 includes power-electronics testing. The probe is rated for 15 A continuous current with a typical contact resistance of 15 mΩ. Spring force is 80 cN at a nominal travel of 0.8 mm.