Technical data
| General | |
|---|---|
| Structure | Basic Contact Probe |
| Type/family | HCF100 |
| Pitch (mm/mil) | 2,54 / 100 |
| Temperature | -45°C...+200°C |
| Dimensions | |
|---|---|
| Total length (mm) | 33.3 |
| Protrusion height (mm) | 8.4 |
| Tip style diameter (mm) | 1.5 |
| Barrel diameter (mm) | 1.37 |
| Materials and surfaces | |
|---|---|
| Tip style | 06 |
| Plunger material | Beryllium copper |
| Plunger plating | Gold |
| Barrel material | Bronze |
| Barrel plating | Silver |
| Spring material | High-grade steel |
| Spring plating | Gold |
| Mechanical specifications | |
|---|---|
| Preload (cN) | 100 |
| Spring force (cN) | 300 |
| Nominal travel (mm) | 4.3 |
| Maximum travel (mm) | 6.4 |
| Pointing accuracy +/- (mm) | 0.08 |
| Electrical specifications | |
|---|---|
| Continuous current (A) | 16 |
| Typical contact resistance (mOhm) | 20 |
Graphics
Beschreibung des Produkts
The High Current Probe HCF10006B150G300A (item number 1092016) is designed for safe transmission of high electrical currents in test and contacting applications. HCF10006B150G300A focuses on current capacity and low transition losses, as required in battery testing, formation and other e-mobility applications. For HCF10006B150G300A, contact resistance, contact force and thermal behavior must be considered together because they influence voltage drop and temperature rise at the contact point. The probe is rated for 16 A continuous current with a typical contact resistance of 20 mΩ. For HCF10006B150G300A, spring force is 300 cN at a nominal travel of 4.3 mm. Tip style 06 (Serrated stepped) has a diameter of 1.5 mm.