Technical data
| General | |
|---|---|
| Structure | Coaxial Probe |
| Type/family | HF77 |
| Pitch (mm/mil) | 19,5 / 748 |
| Dimensions | |
|---|---|
| Total length (mm) | 31.4 |
| Protrusion height (mm) | 19.5 |
| Tip style diameter (mm) 2 | 0.9 |
| Materials and surfaces | |
|---|---|
| Tip style 2 | 02 |
| Spring material | Spring steel |
| Spring plating | Gold |
| Plunger material 2 | Beryllium copper |
| Plunger plating 2 | Gold |
| Spring material 2 | Spring steel |
| Spring plating 2 | Gold |
| Mechanical specifications | |
|---|---|
| Preload (cN) | 450 |
| Spring force (cN) | 600 |
| Nominal travel (mm) | 2.5 |
| Maximum travel (mm) | 3.5 |
| DUT | H-MTD-Female (double) |
| Electrical specifications | |
|---|---|
| Impedance (ohm) | 100 |
| Frequency (GHz) | 20 |
| Internal contact specifications | |
|---|---|
| Nominal travel (mm) 2 | 0.5 |
| Maximum travel (mm) 2 | 0.8 |
| Preload (cN) 2 | 50 |
| Spring force (cN) 2 | 75 |
Graphics
Beschreibung des Produkts
The High Frequency Probe HF77HMTDf0220G1500HMTDmF (item number 1171006) is designed for reliable transmission of high-frequency signals in test and measurement applications. With a defined impedance of 100 Ω, HF77HMTDf0220G1500HMTDmF supports controlled signal routing and helps minimize reflections and signal loss at the test interface. The frequency range extends up to 20 GHz, and this version is intended for contacting H-MTD-Female (double) connectors. On HF77HMTDf0220G1500HMTDmF, spring forces of 600 cN on the outer contact and 75 cN on the inner contact provide defined mechanical contacting.