Language:
Bookmark list ( Products):
HCF73506B400G300A Perspective 1 HCF73506B400G300A Perspective 2

High Current Probes (Battery Contacting) HCF73506B400G300A

Item number 1090970

Technical data sheet

Quantity

Technical data

General
Structure Basic Contact Probe
Type/family HCF735
Pitch (mm/mil) 5,00 / 197
Temperature -45°C...+200°C
Dimensions
Total length (mm) 43.1
Protrusion height (mm) 10.5
Tip style diameter (mm) 4
Barrel diameter (mm) 3.5
Collar diameter (mm) 4
Materials and surfaces
Tip style 06
Plunger material Beryllium copper
Plunger plating Gold
Barrel material Brass
Barrel plating Silver
Spring material High-grade steel
Spring plating Uncoated
Mechanical specifications
Preload (cN) 150
Spring force (cN) 300
Nominal travel (mm) 4.4
Maximum travel (mm) 5.5
Pointing accuracy +/- (mm) 0.1
Thread M3
Tool size (mm) 3,5
Electrical specifications
Continuous current (A) 50
Typical contact resistance (mOhm) 5

Graphics

HCF73506B400G300A Family designation HCF73506B400G300A Diagram HCF73506B400G300A Tip style 1

Beschreibung des Produkts

The High Current Probe HCF73506B400G300A (item number 1090970) is designed for safe transmission of high electrical currents in test and contacting applications. HCF73506B400G300A focuses on current capacity and low transition losses, as required in battery testing, formation and other e-mobility applications. For HCF73506B400G300A, contact resistance, contact force and thermal behavior must be considered together because they influence voltage drop and temperature rise at the contact point. The intended application area for HCF73506B400G300A includes battery and power-electronics testing. The electrical rating of HCF73506B400G300A combines 50 A continuous current with 5 mΩ typical contact resistance. For HCF73506B400G300A, spring force is 300 cN at a nominal travel of 4.4 mm.